Precautions for Handling Geared Motors
Release Date:26/02/2016
Precautions for Handling Geared Motors
▲Temperature range for use:
Geared motors should be used at a temperature of 10~60℃. The figures stated in the catalog specifications are based on use atordinary room temperature approximately 20~25℃.
▲Emperature range for storage:
Geared motors should be stored at a temperature of -15~65℃.In case of storage outside this range, the grease on the gearhead area will become unable to function normally and the motor will becomeunable to start.
▲Relative humidity range:
Geared motors should be used in 20 - 85% relative humidity (no dew condensation).
In a humid environment, the metal parts might rust, causing abnormalities.
Therefore, please be careful about use in such an environment.
▲Turning by output shaft:
Do not turn a geared motor by its output shaft when, for example, arranging its position so as to install it. The gearhead will become a speed-increasing mechanism, which will have harmful effects, damaging the gears and other internal parts; and the motor will turn into an electrical generator.
▲Installed position:
For the installed position we recommend a horizontal position --the position used in our company's shipping inspection.
With
other positions, grease might leak onto the geared motor, the load
might change, and the motor's properties might change from those in the
horizontal position. Please be careful.
▲Installation of geared motor on output shaft:
Please be careful with regard to applying adhesive.
It
is necessary to be careful that the adhesive does not spread along the
shaft and flow into the bearing, etc. Moreover, do not use a silicon
adhesive or other volatile adhesive, as it could harmfully affect
themotor's interior. In addition, avoid press fitting, as it could
deform or damage the motor's internal mechanism.
▲Handling the motor terminal:
Please conduct the welding work in a short time.. (Recommendation: With the soldering iron tip at a temperatureof 340 - 400℃, within 2 seconds.)
Applying
more heat than is necessary to the terminal can melt the motor's parts
or otherwise harm its internal structure. Moreover, applying excessive
force to the terminal area can put stress on themotor's interior and
damage it.
▲Longterm storage:
Do not store a geared motor in an environment where there are materials that can generate corrosive gas, toxic gas, etc., or where the temperature is excessively high or low or there is much humidity. Please be especially careful with regard to storage for lengthy periods such as 2 years or more.
▲Longevity:
The
longevity of geared motors is greatly affected by the load conditions,
the mode of operation, the environment of use, etc. Therefore, it is
necessary to check the conditions under which the product will actually
be used. The following conditions will have a negative effect on
longevity.
Please consult with us should any of them apply.
▲Use with a load that exceeds the rated torque ▲Frequent starting
▲Momentary reversals of turning direction ▲Impact loads
▲Long-term continuous operation ▲Forced turning using the output shaft
▲Use in which the permitted overhang load or the permitted thrust load is exceeded .
▲A pulse drive, e.g., a short break, counter electromotive force, PWM Control
▲Use of a voltage that is nonstandard as regards the rated voltage
▲Use outside the prescribed temperature or relative-humidity range, or in a special environment
▲Please consult with us about these or any other conditions of use that may apply, so that we can be sure that you select the most appropriate model.